Advanced Computing Platform for Theoretical Physics

Commit 12621678 authored by pierog's avatar pierog
Browse files

add ChangeLog file (starting version 1.4 from October 2013)

parent 2813fec9
-------------------------------------------------------------------------------
CRMC version 2.0.0 (08.2021)
-------------------------------------------------------------------------------
Add compatibility with HEPMC3 and direct link to RIVET.
New interface to link CRMC with GEANT4.
Improve precision of energy rescaling to avoid energy violation in lab frame at low energy from nuclear fragments for all models when necessary
Correct Hijing and DPMJET interface.
Improve build system.
-------------------------------------------------------------------------------
CRMC version 1.8.0 (01.2021)
-------------------------------------------------------------------------------
Update DPMJETIII versions (3.06, 3-17.1 and 3-19.1) and limit mass range to light nuclei to avoid problems with old DPMJET 3.0-6.
Update Sibyll to version 2.3d
Add a test on pz conservation and extend array size for cluster in EPOS to avoid stops.
-------------------------------------------------------------------------------
CRMC version 1.7.1 (10.2019)
-------------------------------------------------------------------------------
Extend array in EPOS for safe central heavy ion collisions (some stop otherwise)
Add possibility of sexaquark production in EPOS.
-------------------------------------------------------------------------------
CRMC version 1.7.0 (03.2018)
-------------------------------------------------------------------------------
added small tool to produce cross section tables
update to Sibyll2.3c
update to DPMJETIII-17.1
fix phi particle width in EPOS
-------------------------------------------------------------------------------
CRMC version 1.6.0 (04.2016)
-------------------------------------------------------------------------------
Update Sibyll to version 2.3 including charm production now.
keep original mass of QII to have correct energy conservation (since particles are put on-shell in double precision in crmc now, previous problems with mass in QII are probably solved now)
use the same cross-section in hepmc file and in screen output (sigine in hp and sigineaa in pA/AB)
updated event type definition for sibyll
correct bug in DPMJET interface (impact parameter problem)
-------------------------------------------------------------------------------
CRMC version 1.5.7 (04.2016)
-------------------------------------------------------------------------------
Same as v1.6.0 but with Sibyll 2.1
-------------------------------------------------------------------------------
CRMC version 1.5.6 (10.2015)
-------------------------------------------------------------------------------
Made ROOT-output work again
New option ("-S") to give centre-of-mass energy as input
When compiling, cmake automatically tries to use c++11
For DPMJET, some produced particles could make the program stop during decay
-------------------------------------------------------------------------------
CRMC version 1.5.5 (09.2015)
-------------------------------------------------------------------------------
Restored compatibility with f77 compiler (unsupported trim function)
ROOT dependency is now optional
New option ("-x") to only display cross section for model with set energy and exit
When "ibreit" option is used (for decays with Breit-Wigner masses) the energy rescaling is done after smearing of the energy
Energy balance corrected for QGSJetII (<1 GeV after using original particle masses)
For QGSJetII input energy given as E_lab not E_kin
Functionality for running HIJING model
-------------------------------------------------------------------------------
CRMC version 1.5.3 (07.2014)
-------------------------------------------------------------------------------
HepMC signal vertex propely set
When running DPMJET, use EPOS for decays that have a known Breit-Wigner width to obtain mother/daughter information
Bug correction, DPMJET used impact parameter of first event, always
-------------------------------------------------------------------------------
CRMC version 1.4 (10.2013)
-------------------------------------------------------------------------------
PYTHIA (and models depending on it) now use decay definition as set in crmc
Mother/daughter information can be adjusted for EPOS. istmax=0 only final state, istmax=1 all particles saved
Markdown is supported
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment